Logo Image
JS NEOPLANT CO.,LTD
Inquire Now | Add to Inquiry Cart | Trade Leads
Home | Company Profile | Catalog List
 
Turbo Centrifugal Fan Plant Inquire now
 

Product Description
Turbo Fan Plants.
1)Axial Flow Fan.
2)Centrifugal Fan.
3)GM Blower.
4)Jet type Fan.
5) Multi-stage turbo blower.
6)Turbo Blower.
7)wind tunnel blower.

Product Feature
Essential & Special Features

Whether single-or two-stage for induced draft fans and forced draft fans, or 3-or 4-stage, the fans are always equipped with central hydraulic rotor blade adjustment.

The essen special features of our design are worthy of mention
Compact, stable construction Standardized components for single and two-stage fans ready accessibility to machine parts provided by easilty detachable casing top with horizontal fans and removable rotor unit with vertically mounted fans.
Main bearing system accommodated as compact unit in the centering flanges in the casing.
Fan wheel hub takes the form of a welded structure with heavy inner ring for centrifual force absorption at relatively small diameter (low WK2).
Triple sealing where the blade mounting flange passes through the fan wheel hub
Blades bolted onto mounting flange permit extremely short replacement times
Oil hydraulic rotor blade adjustment with adjustment range down to very low volume flows
Low noise design of flow passage


Comparsion between the Performance Characteristics of Radial Flow and Fans and Axial Flow Fans
In Figure it can clearly be seen that in the case of the variable pitch axial flow fan the curves of constant efficiency pass approximately parallel to the boiler resistance line permitting a larger range operating with good efficiency. In contrast to a radial flow fan with inlet vane control it can be observed that the curves of constant efficiency pass perpendicular to the boiler resistance line, automatically
resulting in a lower efficiency value in the partial load range than in the case of the axial flow fan.
Furthermore, the axial flow fan can be selected in a way that the boiler test block point is that the main operating points are located in the optimum efficiency range.



Service

Thermal Power Station Wind Tunnel Mine Ventilation
Mine Ventilation
Complete Tunnel Ventilation
Iron & Steel work
Chermical & Petrochmical Test Stand
Cement Industry ...etc

One-Stage Induced Draft Fan for
SAMCHONPO T.P.P. UNIT 3 & 4 (560MW)
Rotor Diameter : 3350mm


Product Specification/Models
1.Chemical Industry of Forced Draft Fan
Imp.Dia. = 1850mm
Volume = 200000З/hr
Pressure = 6170mmAq
Power = 4500kw
Efficiency = 86%.

2. Steel Industry of Forced Draft Fan
Imp.Dia. = 3250mm
Volume = 1080000З/hr
Pressure = 1850mmAq
Power = 6850kw
Efficiency = 86%

3.Backward Curved Blade of Centrifugal Type fans
are fitted with backward curved blade which are usually profiled.
They have an aeraulic efficiency frequently in excess of 89%.

Impeller type : Centrifugal
Volume = 983000З/hr
Total Pressure = 1200mmAq
Rotating Speed = 880r.p.m
Power Consumption = 3550kw
Motor Capacity = 4200kw
Impeller Dia. = 2900mm

4.Radial Blade
Radial bladed fans are special designed to solve the problems caused by wear, corrosion, adhesion.

Impeller type : Centrifugal
Volume = 315000З/hr
Total Pressure = 330mmAq
Rotating Speed = 600r.p.m
Power Consumption = 398kw
Motor Capacity = 490kw
Impeller Dia. = 1465mm

5.The wind tunnel
is essential equipment for all kind of aerodynamic experiments and variety of engineering situations such as boundary layer, turbuient and laminar flow, developing a new aircraft and vehicle and investigation to wind effects on ground etc.


Customer : Korea Industitute of Energy & Resources
Range of Wind Velocity = 0~30m/sec
Test Section Size = 2000mm x 2000mm
Length of Test Section = 4000mm
Motor = DC75kW

6.EXCELLENT EFFICIENCY
NO COOLING WATER REQUIRED
SIMPLE CONSTRUCTION & EASY INSTALLATION

The "TURBO", an compact blower developed by US brings together 30 yesrs of experience in the development of GM (gear-increased, single stage) blowers.

External View and Dimensions



Performance Estimate (50З/min x 0.65kg/РG)



Specification

Capacity З/min 35 50
Fluid Air
Discharge kg/РG
Pressure (kpa) 0.55
(53.9) 0.65
(63.8) 0.55
(53.9) 0.65
(63.8)
Shaft Power kW 41 46 55 62
Main Motor Type TEFC
Main Motor output kW 55 75
Main Motor Valtage 440 or 380 V
Weight ton Approximately 1.2
(Including main motor)


7. The Jet fans
are used the longitudinal of relatively short tunnels if natural ventilation of the tunnel is not shufficient.
Jet fans are also used for special ventilation tasks as, for example, the ventilation of patrolling tunnels, setting tanks and similar plants.

The Jet Fans consist of a housing which the impeller with the drive motor is installed, and inlet/outlet silencers which was adapted to the existing demand of noise.
The anti-triction bearings of the motor are greased and designed for continueous working.
The Jet fans are appropriate for an ambient temperature of -25 to 40∩ case of continuous oprtation.

If there is a fire in the tunnel, the jet fans permits a short time operation at high temperature.
FAN TYPE PA-M
DIAMETER(mm) フ630 フ1030 フ1250 フ1530
JET SPEED(m/s) MORE TAHN 30
FLOW RATE(З/s) 8 25 36.8 55
FLOW DIRECTION BIDIRCTIONAL

MOTOR OUTPUT(kW) 11 30 37 55
POLE 2 4 4 6
POWER 440V/380V 60Hz
INSULATION CLASS H

8. SMALL GD

LOW NOISE, LOW VIBRATION

COMPACT LIGHT WEIGHT

EASY INSTALLATION

MAINTENACE FREE


MODEL SELECTION DIAGRAM (click! ¢)



COMMERCIAL ADVANTAGES
GM-Blower ensures high efficiency at the design point and large turn down radio. Those bring clients low electric power consumption.
As mixed Flow impeller is suitable for a large volume of gas, the impeller and blower casing of GM-Blower is 30% smaller than those of conventional centrifugal blowers.
The moment of inertia of rotary parts is small. Consequently, a squirrel cage induction motor which is low in cost and makes easy in maintenance operation can be used.
There are no wear parts due to absence of mechanical touches, continuous operation for a long period is allowed. So the maintenance cost is very small.



Application
1) TUNNEL. MINING TUNNEL.
2) SHIPBUILDING.
3) HIGH FLOOR BUILDING.
4) UNDERGROUND.
5) INDOOR STADIUM.
6) CEMENT FACTORY.
7) GAS REFINEING FOACORY.
8) OIL REFINERY FACTORY.
9) STEEL REFINERY FACTORY.
10) POSINOUS GAS PRODUCT FACTORY.
11) FOOD FACTORY.
12) POWER STATION.
13) CHEMICAL FACTORY.
14) SUBWAY TUNNEL.

Payment
L/C AT SIGHT

Delivery
100DAYS

Origin
MADE IN KORE OR MADE IN CHINA

Minimum Order
1LINE

Packaging
EXPORT STANDARD

Inspection
MAKERS, FINAL

Samples
Not Avaliable


Contact Information
 
JS NEOPLANT CO.,LTD
No.64-102,633Nong ,Wuzhong R/D
ShangHai, Shanghai
China 201103
  • Tel : 86-21-5422-0689
  • Fax : 86-21-6446-4534
  • Homepage : http://jsneoplant.en.ecplaza.net

    Contact :
    Mr. Charles,Jim
    CEO, Manageing.

  • inquire now

     
    Home | Company Profile | Catalog List
    Inquire Now | Add to Inquiry Cart | Trade Leads

    Powered by EC Plaza
    Home | Buy | Sell | My Trade Office | Biz Support | Trade Mall | PR News
    Created by the "Home Page Generator" A free service of EC PLAZA
    Visitors:  059880